Siemens Duct Sensor For Temperature & Humidity – QFM2160
Siemens Symaro Duct sensors for measuring relative humidity and temperature in air ducts of ventilation and air conditioning. The sensors are used as: i) Control sensors in the supply or extract air. ii) Reference sensors, e.g. for shifting the dew point. iii) Limit sensors, e.g. in connection with steam humidifiers. iv) Limit sensors, e.g. for...
Siemens Duct Sensor for Temperature & Humidity – QFM2171
Siemens Duct sensors for measuring relative humidity and temperature in air ducts of ventilation and air conditioning. The sensors are used as: i) Control sensors in the supply or extract air. ii) Reference sensors, e.g. for shifting the dew point iii) Limit sensors, e.g. in connection with steam humidifiers iv) Limit sensors, e.g. for measured...
Siemens Duct Temperature Sensor – QAM2161.040
Siemens Duct Temperature Sensors - QAM2161.040 The QAM… duct temperature sensors are for use in ventilation and air conditioning plants as: • Supply or extract air temperature sensors • Limit sensors, e.g. for minimum limitation of the supply air temperature • Reference sensors, e.g. for compensation of the room temperature as a function of the...
Siemens Immersion Temperature Sensor – QAE3075.010
Siemens QAE3075.010 Immersion Temperature Sensors These sensors are used for acquiring the temperature of liquid or gaseous media (e.g. heating water) in heating, ventilation or air conditioning plants. These are designed for use in connection with automation equipment, display and logging devices.
Siemens Immersion Temperature Sensor – QAE3075.016
Siemens Immersion Temperature Sensors - QAE3075.016 These sensors are used for acquiring the temperature of liquid or gaseous media (e.g. heating water) in heating, ventilation or air conditioning plants. These are designed for use in connection with automation equipment, display and logging devices.
Siemens Room Air Quality Sensors – QPA2062, QPA2062D.
QPA2062D Siemens Room Air Quality Sensors Used in ventilation and air conditioning plants to enhance room comfort and optimize energy consumption by providing demand-controlled ventilation. QPA2062D sensors acquires: CO2 concentrations as an indication of occupancy in rooms where smoking is prohibited. Volatile organic compounds (also called mixed gas)concentrations as an indication of odors such as...
Siemens Room Air Quality Sensors QPA1000
Siemens Room Air Quality Sensors QPA1000, used in ventilation and air conditioning plants to enhance room comfort and optimize energy consumption by providing demand-controlled ventilation. Sensor QPA1000 acquires: CO2 concentrations as an indication of occupancy in rooms where smoking is prohibited. Volatile organic compounds (also called mixed gas) concentrations as an indication of odors such...
Siemens Room Sensor for Humidity and Temperature – QFM3171D
Siemens Room sensors for relative humidity and temperature - QFM3171D The sensors are used as: This sensor is used in ventilation and air conditioning plants where high accuracy and short response times for measuring relative humidity are required. The measuring range covers the entire humidity range of 0…100 %. i) Storage and production facilities in...
Siemens Room Temperature Sensors QAA2071
Room temperature sensors specifically used for acquiring the room temperature. Applicable areas: In heating, ventilation and air conditioning plants for acquiring the room temperature. Function: The sensor acquires the room temperature via its sensing element whose resistance value changes as a function of the temperature. This change is converted to a DC 0...10 V or...